Protective relaying philosophy and design guidelines pjm relay subcommittee july 12, 2018. Differential protection, frame leakage protection the systems in which selectivity is relative are nonunit systems. Zone 3 also provides backup protection for adjacent lines sections. Jun 08, 2019 based on application the protection relay can be categorized asprimary relay.
Types of electrical protection relays or protective relays. Thermal overload protection use for underground power system we are plan to discuss more about this transmission line protection systems in our future articles separately. Transmission line protection free download as powerpoint presentation. Series compensated line protection issues 2 philosophy of the protection of series compensated lines i. The most important advantage of transmission line differential protection function is unaffected to external faults. But most of the time, they are overlooked, and not given much attention, mainly due to its relative size, and being overshadowed by the main relays. The l90 line differential relay and the l60 line phase comparison. Jun 07, 2006 assumed the transmission line from a to b is properly protected by highspeed relaying and backup relaying for all faults. Every element setting affects performance dependability and security. Before considering using a ge multilin relay for a specific transmission line protection application, it is important to understand how the relay meets some more. If the measured impedance is less than the set value, the relay operates and isolates the faulty section. Background series capacitors are almost always added to transmission lines where poor relay performance can have a significant adverse effect on the power system stability. Transmission line protection based on travelling waves.
Jan 04, 2015 however, any relay tester can perform successful endtoend tests with a basic a basic understanding of transmission line protection or 21 impedance protection along and some preparation before. A new transmission line protection 21 video valence. They have replaced the overcurrent protection because of the following reasons. Features include a fourshot recloser, patented capacitance voltage transformer cvt transient overreach logic to enhance security of zone 1 distance elements, and overcurrent elements with directional control, monitoring, and metering. The distance between the fault location and the relay position is calculated by a differential equation of the instantaneous circuit model, which is resolved in a. Apply the sel311c relay for protection, reclosing, monitoring, and control of transmission lines. Best practices for protection and control applications for. Differential relays have to accommodate ct saturation. Rel670 optimized for transmission applications rel670 ieds intelligent electronic device provide versatile protection, monitoring and control functionality with maximum flexibility and performance optimized for transmission overhead lines and cables. Outline of discussion protection and control basics protection fundamentals transmission line protection robust protective relaying scheme design substation configuration power system nerc requirements realworld examples. A distance protective relay evaluates the voltage and current waveforms at the boundary of the protected transmission line and issues a tripping signal to the. Transmission line protection setting calculation relay.
When a fault occurs on a line, the current rises significantly and the voltage collapses significantly. Protective relaying philosophy and design guidelines pjm. Relion protection and control for generation, transmission and sub transmission abb north america english pdf brochure line distance protection rel650 1. Ge multilin application advantages before considering using a ge multilin relay for a specific transmission line protection application, it is important to understand how the relay meets some more general application requirements for. Relion protection and control for generation, transmission and subtransmission abb north america english pdf brochure line distance protection rel650 1. In general, relay engineers have two knobs to adjust when creating settings for a protective element in a relay. Transmission line protection based on travelling waves article pdf available in wseas transactions on circuits and systems 1012. The range of the possible fault current, the effect of load, the question of directionality and the impact of system configuration are all part of the transmission line protection problem. The art and science of line protection all five aspects of performance and reliability are interrelated. Ieee guide for protective relay applications to transmission. Pdf this paper describes an advanced protective relay system for highspeed transmission line protection. Relay are both phasesegregated, current only relays.
Transmission line distance protection explained in detail. Protective relays, associated communication systems, voltage and current sensing. Aug 16, 2017 thermal overload protection use for underground power system we are plan to discuss more about this transmission line protection systems in our future articles separately. Committee on the application of directional ground overcurrent relays. How do we detect and isolate faults on transmission lines. The relion product family offers the widest range of products for the protection, control, measurement and supervision of power systems.
Topics include the selection of communication systems, redundancy, autoreclosing, ground overcurrent protection, line length and source impedance ratio. Figure 6 shows a transmission line protection relay block diagram in a microprocessor relay. Remote backup protection of a transmission line 10. However, any relay tester can perform successful endtoend tests with a basic understanding of transmission line protection or 21 impedance protection along with some preparation before the testing is scheduled to begin. Location of intercircuit faults on doublecircuit transmission line english pdf white paper the. The physical construction of the transmission line is also a factor in protection system application. Which relay is the most affected and which the least affected.
Transmission relay loadability, codified requirements for loadability of phase responsive transmission relays which in some cases significantly limited the ability of some relays to provide backup protection. This protection shall coordinate with dc line protection 0 as a ground fault on the hvdc bus may also operate the dc line protection. This report is prepared for the line protection subcommittee of the power system relaying. This protection shall block before the dc line protection initiate a restart. Implementation of a distance relay to protect transmission line l1 3.
Consider a case of a radial line supplying three substation as shown in. Transmission line differential protection function is one of the most important protection of transmission lines which should issue trip signal without any delay in case of any faults in transmission lines. Where zone 3 element has an offset characteristic, the. Topics include the selection of communication systems, redundancy, autoreclosing, ground overcurrent. Ge multilin application advantages before considering using a ge multilin relay for a specific transmission line protection application, it is important to understand how the relay meets some more general application requirements for simplicity, security, and dependability.
In this post you will get to know everything about the distance protection for the transmission lines. In the paper, we present the highspeed distance element performance, an algorithm that. Transmission line setting calculations beyond the cookbook. Relay at a set to trip instantaneous for faults in its zone. However, any relay tester can perform successful endtoend tests with a basic a basic understanding of transmission line protection or 21 impedance protection along and. The relay is designed to provide fast and selective fault clearance on transmission and subtransmission cables and overhead lines with or without series capacitor compensation. Based on application the protection relay can be categorized asprimary relay. If the measured impedance is less than the reach point impedance, it is assumed that a fault exists on the line between the relay and the. Protection of transmission lines standard j under and over frequency protection including rate of change of frequency element.
Ieee guide for protective relay applications to transmission lines. A new transmission line protection 21 video endtoend testing can appear to be a daunting task. Jul 03, 2014 however, any relay tester can perform successful endtoend tests with a basic a basic understanding of transmission line protection or 21 impedance protection along and some preparation before. Phase relays use linetoline voltage, supplemented by positive sequence voltage, for polarizing, which provides a continuous output for zero voltage phasetophase and doublephasetoground faults. Transmission lines can vary in length from several hundred feet to several. Pdf transmission line protection based on travelling waves. In the years since, we have grown and developed a complete line of products and services for the protection, monitoring, control, automation, and metering of electric power systems. This paper describes an advanced protective relay system for highspeed transmission line protection. Transmission line protection using travelling waves generated at the time of fault are used as trip signals of a travelling wave relay. Dec 26, 2015 protection of transmission lines distance protection by, rohini haridas assistant professor, dept of electrical engineering, ssgm college of engineering,shegaon 2. The basic principle of distance protection involves the division of the voltage at the relaying point by the measured current.
Hence backup relay is slower in action than primary relay. Sel introduced the worlds first digital relay in 1984, revolutionizing the power protection industry by offering fault locating and other features for a fraction of the cost of earlier systems. Transmission and distribution lines protection transmission lines are exposed to short circuits between phases or from phase to ground. This led to other spctf papers illustrating ways to use legacy and. The siprotec 7sa522 relay provides fullscheme distance protection and incorporates all functions usually required for the protection of a power line. Rel670 transmission line distance protection abb group.
Transmission line differential protection based on. Main purpose of the transmission protection relay are to identify the fault of the location. Current comparison is the term used in the psrc guide for protective relay applications to transmission lines for all types of line. Mar 20, 2019 distance protection is a nonunit system of protection, which measures the impedance between the relay location and the point where the fault is incident and compares it with the set value. Basic functions the basic protection function in the rel 100 line protection terminal is a full scheme distance protection with individual measuring elements for different types of faults in different impedance zones. Article calculation of distance protection settings in. Assume that the fault is a transien t fault, so the transmission line goes back into the service after a trip and reclose sequence of a protective relay. Distance protection relay is widely spread employed for the protection of highvoltage ac transmission line and distribution lines. Power system protection college of engineering and. It provides faster protection as compared to overcurrent relay. Transmission line protection distance protection a distance relay measures the impedance of a line using the voltage applied to the relay and the current applied to the relay. Multi function protective relays may be cost effective for generator and line. Included frequency protection in transmission line relays. Current differential line protection setting consideration.
Line protection with distance relays 295 distance relaying should be considered when overcurrent relaying is too slow or is not selective. The methods applied in this example to increase loadability apply equally to zone 1, zone 2, and the highspeed impedance transmission line relays. Primary relay or primary protection relay is the first line of power system protection whereas backup relay is operated only when primary relay fails to be operated during a fault. The basic relay includes three forward and one reverse impedance zone. Protection of transmission lines distance protection by, rohini haridas assistant professor, dept of electrical engineering, ssgm college of engineering,shegaon 2. Electrical power transmission line protection systems. Outline of discussion protection and control basics protection fundamentals transmission line protection robust protective relaying scheme design substation configuration. Pilot line protection there are two main groups of pilot protections. Pole dc differential protection shall have two levels of sensitivity settings, at the lower level. Distance relays are generally used for phasefault primary and backup protection on subtransmission lines, and on transmission lines where highspeed automatic reclosing. Transmission line applications of direction ground. In extreme cases, tripping at the grid and terminal of the transmission line must.
As the length of electrical transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line. Three phase relay circuits are used at two ends of the transmission line. Distance protection is a nonunit system of protection, which measures the impedance between the relay location and the point where. As indicated in 2, it will not be possible to ensure proper performance of the distance protection element for all the possible operating conditions of the mutuallycoupled transmission. The protection principle of this relay is to compare the current inputs at both are high and low. The effect of the equivalent transmission reactance. Pdf advanced transmission line protection system researchgate. Aug 31, 2018 protection of lines or feeder august 31, 2018 february 24, 2012 by electrical4u as the length of electrical power transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of electrical power transformers and alternators. The type of conductor, the size of conductor, and spacing of conductors determines the impedance of the line, and the physical response to short circuit conditions, as well as line charging current.
The trip signal will issue based on the logic function on. Transmission line protection principles ge grid solutions. Paper has made an attempt to obtain travelling waves components in the form of forward wave and backward waves from post fault components of voltage and. Pdf in this paper, a new protection scheme for transmission lines is presented. L pro transmission line protection relay order ing template in order to specify and order an erl relay properly configured for the application, a part number must be constructed as indicated below. Protection of lines or feeder august 31, 2018 february 24, 2012 by electrical4u as the length of electrical power transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of electrical power transformers and alternators. Distance protection for transmission lines siprotec. Transmission line protection relay lpro product overview the lpro provides easy to use, state of the art comprehensive distance and backup directional line protection for all voltages including extra high voltage transmission lines using communication based schemes.